SEN0169-V2
- Capacitors
- Circuit Protection
- Discrete Semiconductors
-
Embedded ICs
- CPLDs (Complex Programmable Logic Devices)
- DSP (Digital Signal Processors)
- Embedded Processors & Controllers
- FPGAs (Field Programmable Gate Array) with Microcontrollers
- Microcontroller or Microprocessor Modules
- Microcontrollers - Application Specific
- Microprocessors
- PLDs (Programmable Logic Device)
- System On Chip (SoC)
-
Interface ICs
- Analog Switches, Multiplexers, Demultiplexers
- CODECs
- Controllers
- Direct Digital Synthesis (DDS)
- Drivers, Receivers, Transceivers
- Encoders, Decoders, Converters
- Filters - Active
- IO Expanders
- Modems - ICs and Modules
- Modules
- Sensor and Detector Interfaces
- Serializers, Deserializers
- Signal Buffers, Repeaters, Splitters
- Signal Terminators
- Specialized
- Telecom
- UARTs (Universal Asynchronous Receiver Transmitter)
- Voice Record and Playback
- LCD
-
Logic ICs
- Logic - Buffers, Drivers, Receivers, Transceivers
- Logic - Comparators
- Logic - Counters, Dividers
- Logic - FIFOs Memory
- Logic - Flip Flops
- Logic - Gates and Inverters
- Logic - Gates and Inverters - Multi-Function, Configurable
- Logic - Latches
- Logic - Multivibrators
- Logic - Parity Generators and Checkers
- Logic - Shift Registers
- Logic - Signal Switches, Multiplexers, Decoders
- Logic - Specialty Logic
- Logic - Translators, Level Shifters
- Logic - Universal Bus Functions
- Memory
- Optoelectronics
- PCB
- Proximity Sensors
- Relays
-
Sensors, Transducers
- Temperature Sensors
- Audio Sensors
- Capacitive Touch Sensors
- Current Sensors
- Environmental Sensors
- Flow Sensors
- Linear Displacement Sensors
- Liquid Level Sensors
- Magnetic Sensors
- Motion & Position Sensors
- Optical Sensors
- Power & Control Sensor ICs
- Pressure Sensors
- Safety Light Curtains
- Sensor Hardware & Accessories
- Vibration & Tilt Sensors
-
Power Management ICs
- DC DC Switching Regulators
- AC DC Converters, Offline Switchers
- Battery Management
- DC DC Switching Controllers
- Display Drivers
- Energy Metering
- Hot Swap Controllers
- Laser Drivers
- LED Drivers
- Lighting, Ballast Controllers
- Linear + Switching
- Linear Transistor Driver
- MOSFET, Bridge Drivers - External Switch
- MOSFET, Bridge Drivers - Internal Switch
- Motor, Bridge Drivers
- OR Controllers, Ideal Diodes
- PFC (Power Factor Correction)
- Power Distribution Switches
- Power Management - Specialized
- Power Over Ethernet (PoE) Controllers
- Power Supply Controllers, Monitors
- RMS to DC Converters
- Special Purpose
- Supervisors
- Thermal Management
- VF and FV Converters
- Voltage Reference
- Voltage Regulators - Linear (LDO)
- Integrated Circuits (ICs)
Your shopping cart is empty!
Product Description
Gravity: Industrial Analog EC / Electrical Conductivity Meter Kit for Water Quality Monitoring (K=1, IP68)
Introduction
The Gravity: Analog pH Sensor / Meter Pro Kit V2 stands out for its industrial-grade durability, exceptional accuracy, and user-friendly design. It is an essential tool for anyone involved in precise water quality monitoring and management.
Industrial-Grade Performance
Designed for continuous operation, this sensor supports 7/24-hour monitoring with a lifespan exceeding 4380 hours, ensuring consistent performance in demanding environments.
Exceptional Accuracy
Achieving a measurement accuracy of ±0.1 pH at 25°C, the device employs a two-point calibration method, enabling users to effortlessly calibrate using standard buffer solutions (4.0 and 7.0). This precision is vital for applications where accurate pH levels are critical.
Robust Design and Compatibility
The sensor operates within a wide voltage range of 3.3 to 5.5V, making it compatible with various main control boards like Arduino and LattePanda. The plug-and-play design, featuring a BNC connector, simplifies setup and reduces installation time.
Arduino Connection Diagram
Attention:
1. The BNC connector and the signal conversion board must be kept dry and clean, otherwise, it will affect the input impedance, resulting in an inaccurate measurement. If it is damp, it needs to be dried.
2. The signal conversion board cannot be directly placed on a wet or semiconductor surface, otherwise, it will affect the input impedance, resulting in an inaccurate measurement. It is recommended to use the nylon pillar to fix the signal conversion board, and allow a certain distance between the signal conversion board and the surface.
3. The sensitive glass bubble in the head of the pH probe should avoid touching the hard material. Any damage or scratches will cause the electrode to fail.
4. After completing the measurement, disconnect the pH probe from the signal conversion board. The pH probe should not be connected to the signal conversion board without the power supply for a long time.
5. The bottle cap of the probe contains protective liquid (3.3mol/L KCL). Even if the bottle cap is screwed tightly, some protective liquid may still leak around the bottle cap, forming white crystals. But as long as there is still protective liquid in the bottle cap, it will not affect the life and accuracy of the probe. So please use it with confidence. It is recommended that the white crystals be poured back into the protective liquid in the bottle cap.
Features
- 3.3~5.5V wide voltage input
- Hardware filtered output signal, low jitter
- Gravity connector and BNC connector, plug-and-play, no soldering required
- The software library supports two-point calibration and automatically identifies standard buffer solution
- Uniform size and connector, convenient for the design of mechanical structures
- Industrial Probe - Support 7*24 Measurement
- Upgraded Transmitter - More Accurate and Stable
Specification
Signal Conversion Board (Transmitter) V2
- Supply Voltage: 3.3~5.5V
- Output Voltage: 0~3.0V
- Probe Connector: BNC
- Signal Connector: PH2.0-3P
- Measurement Accuracy: ±0.1@25℃
- Dimension: 42mm*32mm/1.66*1.26in
pH Probe
- Probe Type: Industrial Grade
- Detection Range: 0~14
- Temperature Range: 0~60°C
- Accuracy : ± 0.1pH (25 ℃)
- Response Time: <1min
- Probe Life: 7*24hours >0.5 years (depending on the water quality)
- Cable Length: 500cm
Shipping List
- pH Probe (Industrial Grade) x1
- pH Signal Conversion Board V2 x1
- Gravity Analog Sensor Cable x1
- Waterproof Gasket x2
- Screw Cap for BNC Connector x1
- M3 * 10 nylon pillar x4
- M3 * 5 screws x8
When you order from opencartworks.com, you will receive a confirmation email. Once your order is shipped, you will be emailed the tracking information for your order's shipment. You can choose your preferred shipping method on the Order Information page during the checkout process.
The total time it takes to receive your order is shown below:
The total delivery time is calculated from the time your order is placed until the time it is delivered to you. Total delivery time is broken down into processing time and shipping time.
Processing time: The time it takes to prepare your item(s) to ship from our warehouse. This includes preparing your items, performing quality checks, and packing for shipment.
Shipping time: The time for your item(s) to tarvel from our warehouse to your destination.
Shipping from your local warehouse is significantly faster. Some charges may apply.
In addition, the transit time depends on where you're located and where your package comes from. If you want to know more information, please contact the customer service. We will settle your problem as soon as possible. Enjoy shopping!